Netgate 5200 Dual System 1U Rack Mount¶
The Netgate 5200 has an optional Dual System 1U Rack Mount Kit available. This page provides an overview for attaching both devices to the rack mount.
Two Netgate 5200 systems in the Dual System 1U Rack Mount¶
Kit Contents¶
The Netgate 5200 Dual System 1U Rack Mount Kit contains all the components necessary to mount two Netgate 5200 devices side-by-side.
The Dual System 1U Rack Mount Kit¶
The kit contains:
1x galvanized steel rackmount platform
4x Long Cable Ties (11.8” / 300mm)
4x Short Cable Ties (3.9” / 100mm)
4x M6 cage nuts, M6 screws and nylon captive washers
Note
The Kit does not include Netgate 5200 devices, nor does it include the AC/DC Power Supply Bricks or AC cables.
Required Tools¶
#3 Phillips (PH3) screwdriver (for M6 rack screws)
Side cutters, scissors, or similar tool to trim cable ties
Rack Mount Assembly Instructions¶
Remove the self-adhesive rubber feet from the bottom side of the devices (if present).
The Netgate 5200 will not fit into the Dual System 1U Rack Mount with the feet installed.
Netgate 5200 systems include four self-adhesive rubber feet (not pre-installed). If converting appliances from a desktop deployment to a rack mount deployment, remove the feet from the bottom of the appliances.
Self-adhesive rubber feet on the bottom side of the device.¶
Thread a large (11.8” / 300mm) cable tie through each of the PSU tie down holes in the rack platform.
Large cable tie placement¶
Place each power supply over a pair of the large cable ties then loosely close the large cable ties around each power supply.
Loosely fasten the power supply in place with the large cable ties¶
Warning
Do not tighten the cable ties yet!
Using the small cable ties, loosely fasten the bundle of Power Supply output wire for each Power Supply.
Warning
Do not tighten the cable ties yet!
Align the device into a channel in the rack platform and gently slide it into place, taking care to align the retention flange on the mount with the matching stepped rabbet in the system enclosure.
Device alignment when sliding into the Dual 1U Rack Mount¶
Continue to gently slide the appliance into the channel in the rack platform until the spring-loaded ball catch (also called a “ball plunger”) clicks, or the appliance reaches the back limit stop on the mounting platform.
Device fully locked in place behind the catch¶
Note
Ensure the bottom of the appliance is flat against the galvanized metal platform or the appliance will not slide properly.
Repeat the previous two steps and gently slide the second device into the rack platform.
Sliding a second device into the Dual 1U Rack Mount¶
Connect the threaded power input connectors to the Netgate 5200 devices.
Connect the power cable to the device¶
Adjust the length of the unfastened portion of the power wires to remove any tension.
Note
To allow removing an appliance from the mounting platform without detaching the entire mount from the rack, leave extra length in the power cable.
Do not put tension on the cable! The cable should have enough length to slide the appliance out of the mount and remove the threaded connector without excessive tension. Before installing the steel mounting platform into the rack, check the length by sliding the system out and detaching the power connector.
Pull the cable ties tightly around the power supplies and the wire bundles.
Tighten the cable ties around the power supply and power cable¶
Trim the excess length from the cable ties
The Netgate 5200 Rack Mount is ready to install into the rack.